Cena s DPH / bez DPH
Hlavní stránka>PD IEC TR 63304:2021 Permanent magnet (magnetically hard) materials. Methods of measurement of magnetic properties in an open magnetic circuit using a superconducting magnet
Sponsored link
sklademVydáno: 2021-05-12
PD IEC TR 63304:2021 Permanent magnet (magnetically hard) materials. Methods of measurement of magnetic properties in an open magnetic circuit using a superconducting magnet

PD IEC TR 63304:2021

Permanent magnet (magnetically hard) materials. Methods of measurement of magnetic properties in an open magnetic circuit using a superconducting magnet

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
8556 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
855.60 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2566.80 Kč
Anglicky Tisk
Skladem
8556 Kč
Označení normy:PD IEC TR 63304:2021
Počet stran:50
Vydáno:2021-05-12
ISBN:978 0 539 17819 7
Status:Standard
Popis

PD IEC TR 63304:2021


This standard PD IEC TR 63304:2021 Permanent magnet (magnetically hard) materials. Methods of measurement of magnetic properties in an open magnetic circuit using a superconducting magnet is classified in these ICS categories:
  • 17.220.20 Measurement of electrical and magnetic quantities
  • 29.030 Magnetic materials

This Technical Report describes the general principle and technical details of the methods of measurement of the DC magnetic properties of permanent magnet materials in an open magnetic circuit using a superconducting magnet (SCM).

This method is applicable to permanent magnet materials, such as those specified in IEC 60404-8-1, the properties of which are presumed homogeneous throughout their volume.

There are two methods:

  • the SCM-Vibrating Sample Magnetometer (VSM) method;

  • the SCM-Extraction method.

This document also describes methods to correct the influence of the self-demagnetizing field in the test specimen on the demagnetization curve measured in an open magnetic circuit. The magnetic properties are determined from the corrected demagnetization curve.

NOTE These SCM-methods can determine the magnetic properties of permanent magnet materials with coercivity higher than 2 MA/m. The methods of measurement in a closed magnetic circuit specified in IEC 60404-5 can lead to significant measurement error due to saturation effects in the pole pieces of yoke for the magnetic materials with coercivity higher than 1,6 MA/m (see IEC 60404-5).