Cena s DPH / bez DPH
Hlavní stránka>PD IEC/TS 62556:2014 Ultrasonics. Field characterization. Specification and measurement of field parameters for high intensity therapeutic ultrasound (HITU) transducers and systems
Sponsored link
sklademVydáno: 2014-05-31
PD IEC/TS 62556:2014 Ultrasonics. Field characterization. Specification and measurement of field parameters for high intensity therapeutic ultrasound (HITU) transducers and systems

PD IEC/TS 62556:2014

Ultrasonics. Field characterization. Specification and measurement of field parameters for high intensity therapeutic ultrasound (HITU) transducers and systems

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9734 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
973.40 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2920.20 Kč
Anglicky Tisk
Skladem
9734 Kč
Označení normy:PD IEC/TS 62556:2014
Počet stran:98
Vydáno:2014-05-31
ISBN:978 0 580 69087 7
Status:Standard
Popis

PD IEC/TS 62556:2014


This standard PD IEC/TS 62556:2014 Ultrasonics. Field characterization. Specification and measurement of field parameters for high intensity therapeutic ultrasound (HITU) transducers and systems is classified in these ICS categories:
  • 17.140.50 Electroacoustics

This technical specification is applicable to high intensity therapeutic ultrasound (HITU) devices, specifying:

  • relevant parameters for quantifying the field;

  • measurement methods at relatively low output levels and methodology for extrapolating these to higher therapeutic level fields;

  • consideration of sidelobes and pre-focal maxima;

  • parameters relevant to HITU transducers of different construction and geometry, including non-focusing, focusing with or without lenses, collimated, diverging and convergent transducers, multi-element transducers, scanning transducers and multiple sources.

This technical specification is intended to support the ultrasonic measurement requirements given in IEC 60601-2-62.

These specifications would have use in quality assurance, safety testing, and the standardization of communications regarding the clinical performance of HITU systems. Where possible, this technical specification incorporates specifications from other related standards.

This technical specification does not apply to the following types of devices, which are covered by other standards:

  • lithotripters (see IEC 61846);

  • surgical equipment (see IEC 61847);

  • physiotherapy devices (see IEC 61689).

Throughout this technical specification SI units are used. In the specification of certain parameters, such as beam-areas and intensities, it may be convenient to use decimal multiples or sub-multiples. For example, beam-area may be specified in cm2 and intensities in W/cm2 or mW/cm2.