Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>PD IEC TS 63070:2019 Ultrasonics. Field characterization. Infrared imaging techniques for determining temperature elevation in tissue-mimicking material and at the radiation surface of a transducer in still air
Sponsored link
sklademVydáno: 2019-02-19
PD IEC TS 63070:2019 Ultrasonics. Field characterization. Infrared imaging techniques for determining temperature elevation in tissue-mimicking material and at the radiation surface of a transducer in still air

PD IEC TS 63070:2019

Ultrasonics. Field characterization. Infrared imaging techniques for determining temperature elevation in tissue-mimicking material and at the radiation surface of a transducer in still air

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6820 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
682.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2046.00 Kč
Anglicky Tisk
Skladem
6820 Kč
Označení normy:PD IEC TS 63070:2019
Počet stran:30
Vydáno:2019-02-19
ISBN:978 0 580 96640 8
Status:Standard
Popis

PD IEC TS 63070:2019


This standard PD IEC TS 63070:2019 Ultrasonics. Field characterization. Infrared imaging techniques for determining temperature elevation in tissue-mimicking material and at the radiation surface of a transducer in still air is classified in these ICS categories:
  • 17.140.50 Electroacoustics

This document is applicable to ultrasonic equipment designed for the medical field of application. It covers both diagnostic and therapeutic (physiotherapy and HITU) equipment.

This document describes transducer evaluation by the infrared imaging technique using a split TMM-phantom for qualitative and quantitative estimation of temperature distributions in tissue-mimicking material, resulting from absorption of ultrasound and from heating of the transducer itself.

This document also describes a method to measure transducer-surface temperature, while the transducer is driven under the still-air condition.

NOTE 1 When the transducer is in contact with tissue-mimicking material, the heating of the transducer itself depends on the actual efficiency of the transducer, on the specific conditions for thermal transfer to or from the tissue-mimicking material, and on the transmitting/receiving electronic circuits, such as a switching circuit or pre-amplifier in some cases.

NOTE 2 The test objects specified in this document are for the measurement of temperature rise and not for the determination of thermal index, which is, by definition in IEC 62359:2010 and IEC 62359:2010/AMD1:2017, an algebraic combination of acoustical field quantities and therefore is not a physically measurable quantity.