Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>PD ISO/TR 18570:2017 Mechanical vibration. Measurement and evaluation of human exposure to hand transmitted vibration. Supplementary method for assessing risk of vascular disorders
Sponsored link
sklademVydáno: 2017-09-11
PD ISO/TR 18570:2017 Mechanical vibration. Measurement and evaluation of human exposure to hand transmitted vibration. Supplementary method for assessing risk of vascular disorders

PD ISO/TR 18570:2017

Mechanical vibration. Measurement and evaluation of human exposure to hand transmitted vibration. Supplementary method for assessing risk of vascular disorders

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4898 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
489.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1469.40 Kč
Anglicky Tisk
Skladem
4898 Kč
Označení normy:PD ISO/TR 18570:2017
Počet stran:22
Vydáno:2017-09-11
ISBN:978 0 580 97551 6
Status:Standard
Popis

PD ISO/TR 18570:2017


This standard PD ISO/TR 18570:2017 Mechanical vibration. Measurement and evaluation of human exposure to hand transmitted vibration. Supplementary method for assessing risk of vascular disorders is classified in these ICS categories:
  • 13.160 Vibration and shock with respect to human beings

This document provides guidance on a supplementary method to that defined in ISO 5349‑1 for measuring and reporting hand-transmitted vibration exposures. The method defined in this document provides an improved assessment methodology for evaluating vascular hand-arm vibration risks (vibration white finger). This document does not apply for other health effects (e.g. sensorineural and musculoskeletal disorders) induced from hand-transmitted vibration exposure (see ISO 5349‑1:2001 , Annex Β).

This document is intended to facilitate future research on hand-arm vibration risks. It can be used to supplement the data given by the ISO 5349‑1 methodology.

This document cannot be used as an alternative to ISO 5349‑1 . Data derived from this document cannot be used in place of ISO 5349‑1 data for fulfilling duties under national regulations, guidance or recommendations for either workplace vibration exposures or machinery vibration emissions.

The methodology defined in this document is based on biomechanical and epidemiological studies which are reviewed in Annex A. Also provided in Annex A is tentative information on a relationship between vibration exposure and risk of developing vascular hand-arm vibration disorders.