Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>PD ISO/TR 3313:2018 Measurement of fluid flow in closed conduits. Guidelines on the effects of flow pulsations on flow-measurement instruments
Sponsored link
sklademVydáno: 2018-03-27
PD ISO/TR 3313:2018 Measurement of fluid flow in closed conduits. Guidelines on the effects of flow pulsations on flow-measurement instruments

PD ISO/TR 3313:2018

Measurement of fluid flow in closed conduits. Guidelines on the effects of flow pulsations on flow-measurement instruments

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9486 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
948.60 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2845.80 Kč
Anglicky Tisk
Skladem
9486 Kč
Označení normy:PD ISO/TR 3313:2018
Počet stran:52
Vydáno:2018-03-27
ISBN:978 0 580 90405 9
Status:Standard
Popis

PD ISO/TR 3313:2018


This standard PD ISO/TR 3313:2018 Measurement of fluid flow in closed conduits. Guidelines on the effects of flow pulsations on flow-measurement instruments is classified in these ICS categories:
  • 17.120.10 Flow in closed conduits

This document defines pulsating flow, compares it with steady flow, indicates how it can be detected, and describes the effects it has on orifice plates, nozzles or Venturi tubes, turbine and vortex flowmeters when these devices are being used to measure fluid flow in a pipe. These particular flowmeter types feature in this document because they are amongst those types most susceptible to pulsation effects. Methods for correcting the flowmeter output signal for errors produced by these effects are described for those flowmeter types for which this is possible. When correction is not possible, measures to avoid or reduce the problem are indicated. Such measures include the installation of pulsation damping devices and/or choice of a flowmeter type which is less susceptible to pulsation effects.

This document applies to flow in which the pulsations are generated at a single source which is situated either upstream or downstream of the primary element of the flowmeter. Its applicability is restricted to conditions where the flow direction does not reverse in the measuring section but there is no restriction on the waveform of the flow pulsation. The recommendations within this document apply to both liquid and gas flows although with the latter the validity might be restricted to gas flows in which the density changes in the measuring section are small as indicated for the particular type of flowmeter under discussion.